Pioneers in the industry, we offer automated environmental titration and multi-parameter analyzers, mt5 potentiometric auto titrator, mantech pecod cod analyzer, automated potentiometric titration system, total acid number (tan) and total base number (tbn) systems for petrochemical analysis and ion chromatography system from India.
₹ 2000000 / Piece Get Latest Price
| Resolution (pH) | 0.001 pH |
| Range (pH) | -2.000 to 20.000 pH |
| Model Name / Number | MT Series |
| Accuracy (mV) | 402 |
| Brand | Mantech |
| Application | Water ,Soil, Food & Beverage |
Minimum order quantity: 1 Piece
Rugged & Reliable: Whether your laboratory requires a simple pH system or a system with eight parameters, MANTECH will deliver. We realize each laboratory is unique and as a result, our systems are tailor configured with off-the-shelf modules to meet your requirements for sample volume, parameters and sample size. Each system is fully automated by easy to use software and robust robotics.
Benefits
· Automates 26-300 samples in a single batch
· Customizable user interface for simplified operation
· IntelliRinse™ prevents cross contamination between samples
· Eliminates potential for human error with automated pipetting using MANTECH’s Titrasip
· Non-destructive sample preparation allows for up to 5 parameters on a single sample
Applications
· Water
· Soil
· Food & Beverage
Parameters
MANTECH can deliver analysis systems that perform the following functions
· pH
· Chloride by Titration or Direct Measure
· Oxygen
· Turbidity
· Alkalinity by Titration
· Fluoride
· Oxidation-Reduction Potential (ORP)
· Nitrate
· Electrical Conductivity
· Color
· Salinity
· Total Hardness
· Acidity by Titration
· Ammonia by Standard Addition or Direct Measure
· Temperature
· Soil pH & Conductivity
₹ 1000000 / Piece Get Latest Price
| Resolution (mV) | 0.1 mV |
| Model Name / Number | MT Series |
| pH Calibration Mode | Linear and multi-line calibrations |
| Power Requirement | 110V to 250V |
| Brand | Mantech |
| Operation | Automated |
Minimum order quantity: 1 Piece
₹ 990000 / Piece Get Latest Price
| Usage/Application | COD Analysis |
| Brand | Mantech Inc |
| Model Name/Number | PeCOD |
| Features | Green technology |
| Automation Type | Automatic, Semi-Automatic |
| Operating Voltage | 220-240 |
Minimum order quantity: 1 Piece
₹ 1000000 / Piece Get Latest Price
| Resolution (mV) | 0.01 mV |
| Resolution (pH) | 0.001 pH |
| Range (pH) | 14.000 pH |
| Usage/Application | Water Analysis: Alkalinity, Hardness, pH, Acidity, Conductivity, Ions |
| Brand | Mantech |
| Model Name/Number | MT-5 |
Minimum order quantity: 1 Piece
MANTECH MT5 automated titration system.
The right alkalinity titration system at the right time, with the right price.
MANTECH’s MT5 marks our evolution to bring simple water quality analyzers to municipal and industrial users. These important users, operating the drinking and wastewater treatment plants, have long suffered with multiple scattered analysis stations to do their critical jobs, and having to “write down” results on bench sheets. The operators try to remember: Is the pH meter calibrated? Is that glass buret with alkalinity titrant purged?, etc. With the NEW MANTECH Pro software, operators and engineers can now benefit from a centralized, simple to use and SMART software system that can do this job, all in one. Parameters include:
· Alkalinity
· pH
· Acidity
· Hardness
· Chloride
· Conductivity
· Residual chlorine
· Turbidity
· “Optimized” TOC
· 10-minute COD/BOD
· Fluoride
· Ammonia
· ORP
· Nitrate
· Salinity
₹ 1000000 / Piece Get Latest Price
| Resolution (pH) | 0.001 pH |
| Accuracy (pH) | 0.001 pH |
| Model Name / Number | MT5 |
| pH Calibration Mode | Automatic |
| End point detection | Automatic |
| Burette Resolution | 0.1 ul |
| Automatic Reagent Addition(s) | Yes |
| Password Protection | Yes |
| Suitable For | Total Acid Number (TAN) /Total Base Number (TBN) |
Minimum order quantity: 1 Piece
TAN / TBN is a required analysis for the petrochemical sector. MANTECH’s automation has made the analysis of these parameters quick and easy. Using multiple static rinse stations ensures that no contamination occurs between samples and that analysis is performed correctly; first the probes are rinsed in toluene, then IPA and then finally in DI water.
MANTECH systems also include an extraction pump to eliminate sample handling after analysis in order to ensure the safety of analysts.
Total Base number (TBN) Analysis experiment measures the quantity of basic components in an oil sample. It can be considered as a measure of the alkalinity of the oil, or of the oil’s ability to neutralize acids produced during combustion.
Total acid number (TAN) experiment measures the quantity of acidic components in an oil sample.
Total acid number (TAN) determination involves the addition of a tri-solvent – made from equal parts of chloroform, toluene and 2-propanol with a small amount of water – to an oil sample. Chloroform is not required, but is used for Total Base Number (TBN) analysis, therefore, the same solvent can be used to avoid manual switching of solvents when both methods are being run. Once dissolved, the sample is titrated with alcoholic potassium hydroxide to an inflection endpoint. A backup set endpoint using the millivolt value from the pH 11 buffer reading during calibration is simultaneously calculated in the case of a weak inflection.
₹ 2500000 / Piece Get Latest Price
| Standard | Conductivity detector |
| Optional | Ampere |
| Detectors | Multiple detectors available |
| Switch | Intelligent switch |
| Maximum Pressure | 42MPa |
| Net Weight(KGS) | 22 |
| Gross Weight(KGS) | 29 |
Minimum order quantity: 1 Piece
₹ 1000000 / Piece Get Latest Price
| Model Name/Number | CY-5 |
| Brand | Boqu Instruments |
| Warranty | 1 Year |
| Display | Direct-reading |
| Measuring Method | Differential pressure method |
| Sample Quantity | 8 |
Minimum order quantity: 1 Piece
CY-5 LABORATORY BOD5 ANALYZER
Pour water sample into a culture bottle with sodium hydroxide in seal cup on bottle mouth, then seal the bottle and put in the incubator, keep the temperature at 20 1 and continuously stirring for 5 days. Organic matter in the sample will be converted to the oxides of nitrogen, carbon and sulfur because of the biological oxidation. During this process, the only gas (CO2) overflow from the sample then is absorbed by sodium hydroxide. At the same time, oxygen consumption of microorganism results in air pressure difference. The BOD5 value can be calculated through measuring the height of the mercury.
Packing list of laboratory BOD5 analyzer
1 BOD main unit, 10 culture bottles, 10 stirrers, 8 CO2 absorption cups, 1 bottle of mercury, rubber conveyer belt ( big and small each 3 strips), 2 airproof circles, 2 fuses, 1 Power AC-DC converter